Electric Motor Repair – From Recognizing Faults to Diagnostic and Motor Repair

LinkedIn
Facebook
Twitter
Email
Print
Electric Motor Repair

Table of Contents

Electric Motor Repair

Electric motors play an important role in running plants with high profitability and efficiency in every industry. Electric motors convert electrical energy into mechanical energy and are necessary for the operation of many types of machines. However, an out-of-commission motor can cause a reduction in production if it is not working at its best level. How should you approach your electric motor repair?

Electric Motor repair: electric motor energy transformation
Electric Motor Energy Transformation

Electric Motor Fault Noises

There are several faults related to both the mechanical and electrical systems that can occur in electric motors. Faults can cause strange noises within the motor, such as mechanical noise, magnetic noise, and windage noise during its operation.

Electric Motor Repair for Mechanical Noise

Mechanical noise is the most typical noise that can come from the electric motor it often relates to the bearings, any loose structural part of the motor, or a loose stator core. If an electric motor has old and rusty bearings, it can cause the motor to take high current while starting or during operation resulting in motor winding failure.

Electric Motor Repair for Windage Noise

Windage noise usually relates to the unexplained sounds that are generated by electric motors. It is common in two or four pole motors and is created by “turbulent airflow [due to] obstructions near the rotating part that moves air”.

Electric Motor Repair for Magnetic Noise

Magnetic noise happens due to the mechanical forces as well as the pressure generated by the magnetizing parts within an electric motor. The most prevalent types of magnetic noise are slip noise and noises from skewing and unequal air gap. It is the second most common reason for strange noise in two or four-pole electric motors and the top reason for noise in electric motors with six or more poles.

Electric Motor Repair Process

Apart from these certain types of noises, a motor winding can be burnt out due to a short circuit or high voltage. If you experience such types of faults in your electric motor, then its time to get it repaired. Reach out to an experienced professional for help.

For the remainder of this article, we will take a look at the process of repairing an electric motor. It’s important to make sure any contractors or specialists you use are experienced and follow appropriate procedures.

Documentation of Electric Motor:

The nameplate of an electric motor is the crucial part that contains all the key information about the motor. Therefore, this information should be documented during the repair of the motor. The nameplate should never be removed; rather, this part should be in kept consideration during the visual inspection of the electric motor.

Pro Tip:
If you don’t have an asset list yet, taking pictures of all your motor nameplates is a quick way to start collecting motor information.

Measuring & Testing:

During the electric motor repairing process, it is necessary to test the components of the motor i.e. journal bearings, bearing housings, the shaft (test for shaft runout, output shaft diameter), and keyways etc. Additionally, the growl test and hot spot test should be done to test the condition of rotor. Apart from visual inspection of motor winding, there are some more tests to check the winding condition such as phase resistance, surge testing, insulation resistance megging, high potential (AC destructive, DC non-destructive tests), and move.

Need Diagnostic Support?

Contact us. We would be more than happy to help!

Machining:

Machining is the vital part of electric motor repairing process for exterior parts and basic metal components. This step covers manufacturing or repairing new shafts, failed housing, and other physical damage repair. One example of machining for electric motors is shaft machining. You can do welding, make a new shaft, or grinding and chrome plating, and straightening of the old shaft. Make sure to use proper grade material as well as heat treat the material, if necessary.

Any machining flaws will impact the health of equipment. Use vibration analysis or other condition testing technique to validate the quality of your equipment upon commissioning a newly machined part.

Dynamic Balancing of Electric Motor:

The next step is the dynamic balancing of the motor’s rotating parts. Balancing plays a key role in the commission and repair process of electric motor. Again, any unbalance will impact the long-term health of equipment. Use vibration analysis or other condition testing technique to validate the quality of your equipment upon commissioning a newly machined part.

Stripping & Rewinding for electric motor repair:

Stripping

Stripping the windings is another significant part of the motor repairing process. It should be done carefully as it protects the motor winding and its lamination. Usually, non-grain oriented electrical steel strips are used as a safe and durable stripping material.

Rewinding

Rewinding is required whenever the winding of electric motor fails due to an electrical surge or a short circuit. Rewinding motors is a detail oriented process which improves the life and performance of your electric motor. Rewinding should be done completely as per manufacturer’s guidelines by using the accurate selection of wire, high quality insulation, phase paper and slot liners. The substandard selection of any of these material may affect the reliability of your motor.

Furthermore, it is preferable to use automated coil winding machines to rewind a faulty motor.

The winding is the most critical part of an electric motor. As such, a professional should still be used, but we will still take a brief look at the process of rewinding for better comprehension;

Electric Motor Repair Stripping & Winding Process

First, before stripping, conduct a core loss test. Then, check and record the physical measurements and cut the head of the winding for the protection of data. Secondly, the proper stripping method will be conducted as described earlier. After that, it is necessary to perform the core loss test again to ensure the safety of the stripping, and that it is not damaging anything. Compare the latest and previous core loss test results to determine whether the hot spots have been removed. For rewinding, it is suggested to use class H (180ºC) thermal resistant triple insulated winding wire should be used to achieve the desired results.

Additionally, the computerized coil winding machines should be used to maintain the coil length, equal inductance, and resistance of every phase. The paper being used for cuff and crease of each slot should be of high quality as well because it will enhance reliability by limiting the vibrations due to maintaining the mechanical rigidity of winding. In the next step, make sure not to damage the enamel of copper wire coils by inserting them carefully in the slots, and for this purpose, a separate sleeve can be used to keep them secure from scratches.

Now, it’s time to tie down each slot. If you want to get the desired results of reliability, then spend some significant time tying down each slot that will make the winding head rigid and limit the vibrations. At last, there is a range of key test to ensure the quality of winding: visual inspection, high potential test, insulation resistance, milliohm resistance, surge test, current record and rotation test etc.

Varnishing: 

Varnishing is that part of motor repair in which the winding is electrically insulated and mechanically protected from vibration and any kind of contamination through resin and varnish. Four basic types are used for varnishing: Dip and Bake Epoxy Varnishing, Trickle Varnishing, Ultra Sealed Winding, and Vacuum Pressure Impregnation. The brief procedure for each type is given below;

Dip and Bake

Dip and Bake is the standard and typical varnish method in which the new motor winding is set to cure or, in simple words, “baked” in an oven after dipping into the varnish tank. This whole procedure is done twice to make sure that the varnish completely covers the winding. It is necessary to allow the winding to cool down after the first round of dip and bake because if the winding is still hot for the second round, the first varnish coating can run off the winding due to being more viscous and results in a less effective second coat of varnish. The varnish should be high quality, and Hermetic rated so it can withstand the high temperature.

Trickle Varnishing

In Trickle Varnishing method, the winding is first fastened with a rotating table and wires and then revolved and heated by using the electrical resistance. As soon as the temperature rises, a small amount of varnish is poured onto the head of winding which flows throughout the each slot and eliminates any chance of partial discharge in random winding. After complete saturation, the varnish is cured on the machine by increasing the current in the winding. Since the varnish is cured on the machine, this varnish method is much better and speedy than the dip and bake method and can be used in emergency repair conditions.

Vacuum Pressure Impregnation Method

In the Vacuum Pressure Impregnation method, the winding is fully infused in varnish or resin by placing it in a varnish-filled vacuum pressure tank. At the start, the winding is preheated and placed in an almost 10ft. diameter tank. Then vacuum is created, and let the varnish or resin completely covers the winding by pressurizing the tank. During the whole process, the capacitance is specially checked to ascertain the quality of varnishing. This method is comparatively time-consuming as each cycle is set multiple times. Furthermore, this technique is usually applied on medium voltage motors and form coil systems. Because the motor windings and insulation tapes may not get saturated in varnish coating in typical varnish techniques. 

Ultra Seal Winding

Ultra Seal Winding is an advanced method for insulating the motor winding that provides complete protection against contaminations, moisture, and temperature. The winding is fully infused and sealed with high molecular weight thermoset polymer resin in this method. Ultra seal winding is recommended for electric motors that need to be installed in extreme weather conditions and contaminations.

Re-assembling, Testing & Painting: 

After rewinding and varnishing, the electric motor is re-assembled and tested to meet the quality control procedures. At the final stage of motor repairing, the motor is painted to give it a new and fresh look. That being said, the motor label or the motor nameplate must stay visible and legible after the painting.

Reference Links:

Leave a Comment

Your email address will not be published. Required fields are marked *