In vibration analysis, ensuring the quality of data is essential for accurate insights. This article explores the various settings and metrics that impact data quality, such as sampling time, resolution, and dynamic range. By understanding these parameters, analysts can optimize their measurements and overcome challenges in data acquisition and analysis.
Nyquist theorem: Sampling time based on frequency of interest
Sample Rate and Resolution
The maximum frequency that you can accurately measure (or the Fmax boundary) is determined by the sampling rate. Since the sample rate must be at least 2.56 times the highest frequency of interest, the only parameter that you can adjust that will affect these are your maximum and minimum frequencies.
The sample rate is controlled by selecting the Rmx
Data Quality Metrics – What’s the difference between the sampling rate and the total number of samples?
The sampling rate is controlled by selecting Fmax. The number of samples is defined by the lines of resolution.
Sample rate is proportional to frequency range
F_S=2.56 * F_Max
Another important parameter is the Lines of Resolution or LOR. On most modern data collectors, Lines of Resolution (LOR) is a setting.
Lines of Resolution= LOR=N/2.56
The number of samples needed is dependent and proportional to the Lines of Resolution (LOR).
Number of samples= N=2.56 (LOR)
Resolution is also an important data quality metric, and this metric is somewhat counterintuitive. In the English language, a high-quality reading with many sample spots would be referred to as “high resolution”. For example, the concept of resolution is frequently discussed in digital photography. If you increase the resolution, you increase the pixel count. As resolution increases, the factor R decreases. Think of the factor R as the distance between data points.
Resolution=R=F_max/LOR
Smaller distance between points=Low R
Larger distance between points=High R
“Low R” has higher resolution than “High R”
So why not always take high resolution data?
There is a downside to high-quality, high-resolution data: Sample Time. A higher resolution spectrum requires more data be collected than a lower resolution spectrum would require. This means that the analyzer will take more time to collect, process, and store this data, and more time will be required during data acquisition. Vibration data acquisition technicians and analysts will spend more time next to the machines, collecting data. Higher-resolution spectra will also take up more space in the memory of your data collector, but as technology is improving and more data collectors and analyzers are coming to market, and with improved memory space and processing speed, constraints are expanding and we are able to get better quality data and thus, we are able to perform more detailed analysis.
The time equations below show how to calculate the sample time, T.
Sample Time=T=N/F_S =(Number of Samples)/(Sampling Rate)
T=LOR/F_max
Dynamic Range
Dynamic range is the ability to see low amplitude peaks in the presence or around higher amplitude peaks – think about sidebands. This is important data you could miss due to poor dynamic range.
Low amplitude signals can be overcome or drowned out by higher amplitude signals. The low amplitude signals could be what tells you the condition of the machine. This is a real problem and could cause an analyst to miss a diagnosis. Dynamic range is vital.
Dynamic range used to create additional constraints that data analysts worked with and around. However, with improving technology, dynamic range errors are less common.
A large or wide dynamic range means you can see very small signals even in the presents of large signals. With an insufficient dynamic range, the time waveform may look “chunky” with inconsistent and unpatterned appearing data.
Dynamic Range=20 log((Smallest Signal)/(Greatest Signal))
This is a more common issue to see in units from the 1990s. Current/modern analyzers have a much better dynamic range which nullifies the issue many old analyzers would have an auto-ranging issue or delayed reading output.
T=T_S N=N/F_S =N/(2.56F_max )=LOR/F_max
Need help?
Book a Call with Our Industrialization Consultant
Never Stop Learning
Check out more of our blog for more articles on mechanical and industrial engineering and engineering education.
Need help?
Book a Call with Our Industrialization Consultant
Ready to Learn More?
Check out more of our blog for more articles on mechanical and industrial engineering.




3 thoughts on “Vibration Analysis Data Quality Settings & Metrics -Sampling Time, Resolution, & Dynamic Range”
I want to to thank you for this wonderful read!! I absolutely loved every little bit of it. I have you saved as a favorite to look at new stuff you postÖ
It’s nearly impossible to find educated people in this particular subject, but you seem like you know what you’re talking about when it comes to vibration analysis! Thanks
There’s not enough FREE information out there on vibration analysis data quality settings. Honestly, there isn’t a lot of free vibration analysis education at all. Thank you for not charging and arm & leg for this!